je@jeeyvee.com
This unit consists of a hermetically sealed compressor with air cooled condenser. A capillary or expansion valves are next to condensers followed by medium temperature evaporators. Electrical energy supplied to the compressor can be measured by energy meter. This Test Rig is used to perform the following experiments:
To calculate the COP of unit.
To calculate the refrigerating effect and HP of unit.
To determine the sensible heat factor of air.
Compressor : 1.5 ton (5522)
Air cooled condenser : Suitable for above compressor with suitable cooling fan.
Expansion device : Capillary tube.
Evaporator coil : Suitable for above compressor immersed in duct.
Refrigerant : Freon - 22.
Energy meter for power measurement of compressor
Pressure gauges : 2 Nos. for high and low pressure.
Thermometer : (a) Glass type dry and wet bulb thermometer - 2 Nos. (b) Temperature sensors - 5 Nos.
Digital Temperature Indicator : 6-Channel
Temperature sensor (Thermocouple) : 6 Nos.
Service valves : 3 Nos. needle type.
Ammeter : 1 No.
Voltmeter : 1 No.
Thermostat : 1 No.
Filter/drier : 1 No.
The equipment is mounted on a sturdy frame with control panel.